Table of Contents

Hardware

Most current information

You can find the most current information about the Beijing module at
http://www.grodansparadis.com/vilnius/vilnius.html. On the site you can also find links to the latest firmware, drivers and schematics etc for its use.

Installing the module

Connect the module to the CAN4VSCP bus. The red LED on the module should light up indicating that the device is powered. If this is the first time you start up the module the green lamp next to the initializing button will start to blink. This means that the module is trying to negotiate a nickname address with the rest of the modules on the bus. When it found a free nickname the green LED will light steady. If the green led does not start to blink press the initialization button until it does.

Now your module is ready to use.

The raw facts

Parameter Value
Current hardware reversion B
Current firmware version See here
Supply voltage +9-+28 VDC
PCB Size 42mm x 72mm
Power requirements 0.1W
Communication: CAN4VSCP (CAN) 125 kbps
Number of channels 4
Measurement range 0-5V and 0-10V
A/D resolution 10 bits

Schematics

Schematics: Rev B (click picture to enlarge)

Components

Connectors

Terminal block

Pin Description
1 +5V (VCC)
2 IN0A
3 IN0B
4 IN1A
5 IN1B
6 IN2A
7 IN2B
8 IN3A
9 IN3B
10 I/O 1
11 I/O 0
12 Ground (GND)

RJ-XX pin-out

The unit is powered over the CAN4VSCP bus. The CAN4VSCP normally uses CAT5 or better twisted pair cable. You can use other cables if you which. The important thing is that the CANH and CANL signals uses a twisted cable. For connectors you can use RJ10, RJ11, RJ12 or the most common RJ45 connectors.

Recommended connector is RJ-34/RJ-12 or RJ-11 with pin out as in this table.

Pin Use RJ-11 RJ-12 RJ-45 Patch Cable wire color T568B
1 +9-28V DC RJ-45 Orange/White
2 1 +9-28V DC RJ-12 RJ-45 Orange
3 2 1 +9-28V DC RJ-11 RJ-12 RJ-45 Green/White
4 3 2 CANH RJ-11 RJ-12 RJ-45 Blue
5 4 3 CANL RJ-11 RJ-12 RJ-45 Blue/White
6 5 4 GND RJ-11 RJ-12 RJ-45 Green
7 6 GND RJ-12 RJ-45 Brown/White
8 GND RJ-45 Brown

RJ-11/12/45 pin-out RJ-11/12/45 pin-out

:!: Always use a pair of twisted wires for CANH/CANL for best noise immunity. If the EIA/TIA 56B standard is used this condition will be satisfied. This is good as most Ethernet networks already is wired this way.

Inter module connector

The inter module connector can be used to connect modules that are physically close to each other together in an easy way. Remember that the minimum length of a connection cable is 30 cm.

Pin Description
1 Power from CAN4VSCP bus
2 CANH
3 CANL
4 GND


PIC programming Connector

pin Description
1 Reset
2 VCC
3 GND
4 PGD (RX of second serial port is here to)
5 PGC (TX of second serial port is here to)
6 LWPGM


Functionality of the status LED

The LED is used to indicate the status of the module. It will light steady when the firmware is running and will blink when the module is in the nickname discovery process.

LED Description
Steady No error. Firmware running.
Blinking Module is going through the nickname discovery process.

CAN

CAN4VSCP is a CAN based bus running at 125 kbps with the addition of DC power. If you are interested in how CAN works you have a pretty good intro here.

CAN is known to be robust and is there for used in vehicles and in the industry.



Paradise of the Frog AB Brattbergavägen 17, 820 50 LOS, SWEDEN
email: info@paradiseofthefrog.com phone: +46 (0)8 40011835
web: http://www.paradiseofthefrog.com