A VSCP unit is describing it's configuration to the world with a register model where each register is eight bit in width. This is often inconvenient for a human user who is used to higher level types and this is what abstractions are there for. They sit above registers and specify types as strings, floats, integers and other such higher level types.

A/D value

Name Type Description
ch0_value uint16_t A/D value for channel 0
ch1_value uint16_t A/D value for channel 1
ch2_value uint16_t A/D value for channel 2
ch3_value uint16_t A/D value for channel 3

Measurement value

Name Type Description
ch0_measurement_value float Measurement value for channel 0
ch1_measurement_value float Measurement value for channel 1
ch2_measurement_value float Measurement value for channel 2
ch3_measurement_value float Measurement value for channel 3

A/D report interval

Name Type Description
ch0_report_interval uint16_t Report interval in milliseconds for channel 0. Set to zero to disable.
ch1_report_interval uint16_t Report interval in milliseconds for channel 1. Set to zero to disable.
ch2_report_interval uint16_t Report interval in milliseconds for channel 2. Set to zero to disable.
ch3_report_interval uint16_t Report interval in milliseconds for channel 3. Set to zero to disable.

A/D low alarm

Low alarms will use index 0,1,2,3 to identify the origin of the alarm. See Events for more information.

Name Type Description
ch0_low_alarm uint16_t Low alarm set point for channel 0.
ch1_low_alarm uint16_t Low alarm set point for channel 1.
ch2_low_alarm uint16_t Low alarm set point for channel 2.
ch3_low_alarm uint16_t Low alarm set point for channel 3.

A/D high alarm

High alarms will use index 0x80,0x81,0x82,0x83 (bit 7 set of the index byte) to identify the origin of the alarm. See Events for more information.

Name Type Description
ch1_high_alarm uint16_t High alarm set point for channel 0.
ch2_high_alarm uint16_t High alarm set point for channel 1.
ch3_high_alarm uint16_t High alarm set point for channel 2.
ch4_high_alarm uint16_t High alarm set point for channel 3.

Measurement report interval

Name Type Description
ch0_measurement_report_interval uint16_t Measurement report interval for channel 0. Set to zero to disable.
ch1_measurement_report_interval uint16_t Measurement report interval for channel 1. Set to zero to disable.
ch2_measurement_report_interval uint16_t Measurement report interval for channel 2. Set to zero to disable.
ch3_measurement_report_interval uint16_t Measurement report interval for channel 3. Set to zero to disable.

A/D absolute low value

Name Type Description
ch0_low uint16_t Absolute low value for channel 0
ch1_low uint16_t Absolute low value for channel 1
ch2_low uint16_t Absolute low value for channel 2
ch3_low uint16_t Absolute low value for channel 3

A/D absolute high value

Name Type Description
ch0_high uint16_t Absolute high value for channel 0
ch1_high uint16_t Absolute high value for channel 1
ch2_high uint16_t Absolute high value for channel 2
ch3_high uint16_t Absolute high value for channel 3

k constants for linearization

Linearization is available so a measurement y can be calculated from

y = k*x + m

where x is either the current counter value for a channel or the current frequency for a channel.

Name Type Description
ch0_k float k-constant for linearization of channel 0 A/D value
ch1_k float k-constant for linearization of channel 1 A/D value
ch2_k float k-constant for linearization of channel 2 A/D value
ch3_k float k-constant for linearization of channel 3 A/D value

m constants for linearization

Linearization is available so a measurement y can be calculated from

y = k*x + m

where x is either the current counter value for a channel or the current frequency for a channel.

Name Type Description
ch0_m float m-constant for linearization of channel 0 A/D value.
ch1_m float m-constant for linearization of channel 1 A/D value
ch2_m float m-constant for linearization of channel 2 A/D value
ch3_m float m-constant for linearization of channel 3 A/D value