Abstractions

A VSCP unit is describing it's configuration to the world with a register model where each register is eight bit in width. This is often inconvenient for a human user who is used to higher level types and this is what abstractions are there for. They sit above registers and specify types as strings, floats, integers and other such higher level types.

Counters

Real time counter values that will increase or decrease over time, depending on settings in the counters control register, if a pulse is available on the channel.

Name Type Description
counter0 uint32_t Counter for channel 0
counter1 uint32_t Counter for channel 1
counter2 uint32_t Counter for channel 2
counter3 uint32_t Counter for channel 3

Frequency

Frequency for the signal on the channel.

Name Type Description
frequency0 uint32_t Frequency for channel 0
frequency1 uint32_t Frequency for channel 1
frequency2 uint32_t Frequency for channel 2
frequency3 uint32_t Frequency for channel 3

k constants for linearization

Linearization is available so a measurement y can be calculated from

y = k*x + m

where x is either the current counter value for a channel or the current frequency for a channel.

Name Type Description
ch0_k float A 32-bit floating point k-constant for linearization of channel 0 counter/frequency value.
ch1_k float A 32-bit floating point k-constant for linearization of channel 1 counter/frequency value.
ch2_k float A 32-bit floating point k-constant for linearization of channel 2 counter/frequency value.
ch3_k float A 32-bit floating point k-constant for linearization of channel 3 counter/frequency value.

m constants for linearization

Linearization is available so a measurement y can be calculated from

y = k*x + m

where x is either the current counter value for a channel or the current frequency for a channel.

Name Type Description
ch0_m0 float A 32-bit floating point m-constant for linearization of channel 0 counter/frequency value.
ch1_m1 float A 32-bit floating point m-constant for linearization of channel 1 counter/frequency value.
ch2_m2 float A 32-bit floating point m-constant for linearization of channel 2 counter/frequency value.
ch3_m3 float A 32-bit floating point m-constant for linearization of channel 3 counter/frequency value.

Counter alarm levels

Counter alarm level. If the counter go above (or below) this value an alarm will be issued (if active). The alarm will be flagged in the alarm register and the alarm condition is rested if the counter value goes below counter value - hysteresis.

Name Type Description
cnt0_alarm_level uint32_t A 32-bit counter alarm level for channel 0.
cnt1_alarm_level uint32_t A 32-bit counter alarm level for channel 1.
cnt2_alarm_level uint32_t A 32-bit counter alarm level for channel 2.
cnt3_alarm_level uint32_t A 32-bit counter alarm level for channel 3.

Counter hysteresis

Counter hysteresis is the value the counter should drop with before an alarm condition is no longer active. This means that the next time the limit is passed the alarm condition is active again.

Name Type Description
cnt0_hysteresis uint16_t A 16-bit counter hysteresis value for channel 0.
cnt1_hysteresis uint16_t A 16-bit counter hysteresis value for channel 1.
cnt2_hysteresis uint16_t A 16-bit counter hysteresis value for channel 2.
cnt3_hysteresis uint16_t A 16-bit counter hysteresis value for channel 3.

Counter reload values

This is a value reloaded (if activated) to the counter when it counts down to zero.

Name Type Description
cnt0_reload uint32_t A 32-bit counter reload value for channel 0.
cnt1_reload uint32_t A 32-bit counter reload value for channel 1.
cnt2_reload uint32_t A 32-bit counter reload value for channel 2.
cnt3_reload uint32_t A 32-bit counter reload value for channel 3.

Frequency low alarms

Frequency low alarm level. Alarm condition is active if the frequency goes below this value. The alarm condition is active until the frequency go up to a value that is this value plus configured frequency hysteresis.

Name Type Description
freq0_alarm_low uint16_t A 32-bit low alarm level for frequency 0.
freq1_alarm_low uint16_t A 32-bit low alarm level for frequency 1.
freq2_alarm_low uint16_t A 32-bit low alarm level for frequency 2.
freq3_alarm_low uint16_t A 32-bit low alarm level for frequency 3.

Frequency high alarms

Frequency high alarm level. Alarm condition is active if the frequency goes above this value. The alarm condition is active until the frequency go down to a value that is this value minus configured frequency hysteresis.

Name Type Description
freq0_alarm_high uint16_t A 32-bit high alarm level for frequency 0.
freq1_alarm_high uint16_t A 32-bit high alarm level for frequency 1.
freq2_alarm_high uint16_t A 32-bit high alarm level for frequency 2.
freq3_alarm_high uint16_t A 32-bit high alarm level for frequency 3.

Frequency hysteresis

This is the hysteresis used for frequency high/low alarms.

Name Type Description
freq0_hysteresis uint16_t A 16-bit hysteresis value for frequency 0.
freq1_hysteresis uint16_t A 16-bit hysteresis value for frequency 1.
freq2_hysteresis uint16_t A 16-bit hysteresis value for frequency 2.
freq3_hysteresis uint16_t A 16-bit hysteresis value for frequency 3.